£0
- Brand: NAPIT
- Sku: SM25435UK
- Availability: In Stock
✔️Immediate download
✔️Highlighting, editing, saving and printing are available
✔️The same content as in a hardcover book
✔️Search for words within the text
✔️For any PDF file viewers and devices
How to download
Register on this website and pay for your selected book.
After you have paid, go to "My Account"-"Downloads" section. There you will see a PDF file. Download and open it. It contains a link to download your book. Click on the link and download your book.
You can send us a message that you want to receive the book to your e-mail, and a link to download the book will also be sent to your e-mail.
About the book:
Publisher: NAPIT
Place of Publication: United Kingdom
Pages: 179
Edition: 2022
Language: English
Size: 63 Mb
Complies with BS7671:201 8+A2:2022.
Content:
Preface
Foreword
Introduction
Part 1 Electrical Installation Condition Report (EICR): Observations and Codes
Section 1.0: External Condition of Intake Equipment
Section 2.0: Presence of adequate arrangements for other sources such as Microgenerators
Section 3.0: Earthing/Bonding Arrangements
Section 4.0: Distribution Boards& Consumer Units
Section 5.0: Distribution and Final Circuits
Section 6.0: Locations Containing a Bath or a Shower
Section 7.0: Other Special Installations or Locations
Part 2 Risk Assessment for Omission of an RCD
Part 3 Frequency of Next Inspection
Part 4 Information for Clients
4.1 Observation Codes and what you need to do
4.2 Electricity Distribution Business (DB) Equipment, DNOs, Meter Operators, Electrical Suppliers and ESQCRs
4.2.1 Reporting suspected damaged supplier's equipment to the DNO/MO
4.2.1.1 Reporting process
4.3 Social housing
4.3.1 Visual inspection of whole installation: Routine Operational Visual Inspection (Electrical) (ROVI)
4.3.2 Electrical Installation Condition Report (EICR)
4.3.3 Electrical Installation Condition Report (EICR) Limitations
4.3.4 Types of Limitations
Part 5 Information for Inspectors
5.1 Asbestos
5.2 Max 100% and 80% Zs values for BS EN 60898 and BS3871 circuit-breakers and RCBO's BS EN 61009
5.3 80% Z values for BS 88-2, BS88-3, BS 3036, BS1361/2, BS3871, BS EN 60898 and BS EN 61009-1
5.4 Installation Reference Methods and Conductor csa Current Ratings for PVC Insulated Flat Cable with Protective Conductor (T&E)
5.5 Testing Characteristics of Different Types of RCD
5.5.1 RCD Test Instruments
5.6 Surge Protective Devices (SPDs)- Inspection check routine
5.6.1 Changes SPD Requirements for BS7671:2018+A2:2022
5.7 Ring Final Circuits and Radial Final Circuits
5.7.1 Ring - Final Socket-Outlet Circuit
5.7.2 Radial- Final Socket-Outlet Circuit
5.8 Arc Fault Detection Devices (AFDD)
5.8.1 IR Testing with AFDDs in circuit
5.8.2 Earth Fault Loop Impedance testing with AFDD in circuit
Part 6 Non-Codable Observations
6.1 Non-Codable Observations
6.2 Proximity of Gas Meter/Pipes to Electrical Inta&